Features:
The Double Float
® Master pump switch is a mechanically activated pump switch which provides automatic control of pumps in non-potable water and sewage applications.
The Double Float® Master pump switch consists of two mechanical floats and a splice tube. The splice tube contains a holding relay which enables the floats to function in series.
The holding relay eliminates pump chatter in turbulent conditions allowing the Double Float
® Master pump switch to operate relay control panels for larger pump applications.
The Double Float® Master pump switch features:
• Encapsulated relay and splice provides reliable seal
• Controls pumps up to 15 FLA, 90 LRA, 120V or 240V
• Adjustable pumping range of 3 to 48 inches (7.6 to 122 cm) with increased pumping range up to 6 feet (1.8 m) available
• Floats are labeled for ease of installation
• Reliable, mechanical alternative for areas restricting the use of mercury
• CSA Certified; Three-year limited warranty
Specification:
• Cable attached to float housing: flexible 18 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE)
• Cable above splice: flexible 14 gauge, 3 conductor (UL, CSA) SJTW, waterresistant, thermoplastic
• FLOATS: 2.74 inch diameter x 4.83 inch long (7.0 x 12.3 cm) high impact, corrosion resistant, PP housing for use in sewage and non-potable water up to 140
oF (60
oC)
• ELECTRICAL:
120 VAC 50/60Hz Single Phase:
Maximum Pump Running Current (FLA): 15 amps
Maximum Pump Starting Current (LRA): 90 amps
240 VAC 50/60Hz Single Phase:
Maximum Pump Running Current (FLA): 15 amps
Maximum Pump Starting Current (LRA): 90 amps
NOTE: This switch must be used with pumps that provide integral thermal overload protection.
Installation:
Mount the float switch:
Failure to mount floats as outlined below may inhibit switch operation.
1. Determine pumping range for installation as shown in Figures B & C.
2. If floats are mounted less than 16 inches (40.6 cm) apart, mount floats at a 90o angle from each other as shown in Figure B.
3. Place cord into clamp as shown in Figures A and B.
4. Locate the clamp at the desired activation level and secure to discharge pipe as shown in FigureA.
NOTE: Top and bottom floats are labeled. Ensure they are mounted per Figures B & C.
5. Tighten the hose clamp using a screwdriver. Over tightening may result in damage to the plastic clamp. Make sure the float cable is not allowed to touch the excess hose clamp band during operation.
6. Mount the top fl oat in a similar manner. Stow excess cable away from float operation.
7. Check installation. Allow system to cycle to insure proper operation.
NOTE: All hose clamp components are made of 18-8 stainless steel. See your SJE-Rhombus supplier for replacements.
Piggy-back plug install:
Electrical outlet must not be located in pump chamber.
Electrical outlet voltage, piggyback plug voltage, and pump voltage must match.
1. Follow steps 1 through 6 of "Mounting The Switches."
2. Insert 120 VAC piggy-back plug into 120 VAC outlet or 230 VAC piggy-back plug into 230 VAC outlet.
3. Plug pump into piggy-back plug as shown in Figure B.
4. Check installation. Allow system to cycle to insure proper operation.
SJE-Rhombus (S. J. Electro Systems, Inc. ) was founded on July 2, 1975 by Steve Johnston. Over 40 years later, SJE-Rhombus has grown into a leading manufacturer of reliable, trouble-free liquid level controls for the water, wastewater and sewage industries throughout the United States and Canada, as well as into global markets.
SJE-Rhombus offers a wide variety of control products for residential, commercial, municipal, and industrial markets. From control panels utilizing embedded circuit board technology, to complete control and monitoring systems designed and built to individual specifications, SJE-Rhombus represents the most reliable integration of engineering and manufacturing capabilities in the industry.
SJE Rhombus Suzhou factory is 100% subsidiary company of SJE Rhombus. We offer a wide variety of control products for residential, commercial, municipal, and industrial markets. We had ISO9001: 2008 certification, and UL, cUL, CSA, TUV, CE certification. From float switches, alarms, control panels to complete control monitoring systems designed and built to individual specifications, SJE-Rhombus represents the most reliable integration of engineering and manufacturing capabilities in the industry.
New product desgins endure extensive in-house and field testing before submittal to recognized independent laboratories for safety testing and approval (UL, cUL, CSA, CE). Each product is constructed of materials of the highest quality with expert workmanship and delivered in responsive lead times. This commitment to quality ensures you a dependable, trouble-free product.
·The manufacturing process, quality control standard of Suzhou factory is completely complied with SJE Rhombus DL's.
·We have complete float switch production line, including cord sets line, plug molding, float housing welding, epoxy sealing, and inspection.
1) Can I have some samples ?
Yes ,we can send you samples for testing,contact us for details
2) What's delivery time ?
For standard level regulator 5m, 10m, 20m ,it usually takes about 7 working days;
For non-standard,it usually takes 30 days ,please contact us for details;
3) Can I do OEM or ODM ?
Yes, we have our own engineering team and we do accept OEM and ODM,but there is ordering quantity requirement;
4) How does your factory do the quality control ?
Our production process follow up the ISO standard and we control the product quality according to UL, CSA, TUV certification standard. All the manufacturing process are fully comply with SJE USA factory standard.
5) What is the warranty ?
We provide 5 - Years Limitted warranty for MegaMaster